Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

Conductive Level Limit Switch LKL-P*

Conductive Level Limit Switch LKL-P*
Conductive Level Limit Switch LKL-P*

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 31974
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • Level limit switch for conductive liquids
  • Detect up to five level limits with one probe
  • Flexible instrumentation
  • No moving parts in the tank
  • No calibration: quick and low-cost start up
  • Option between rod or rope version for optimum adaptation to the application
  • Two-point control and additional maximum and minimum detection
  • Approval as overfill protection and leak detection system acc. to WHG
Параметр Значение
Общие характеристики
Артикул 31974
Материал probes: - rods: rod 1.4404/316L, insulation: PP - ropes: rope 1.4571/316Ti, insulation FEP, weight 1.4435/316L housing: - output NA (separate instrument version): housing PPS, cover PBT - output E5/WA/N1 (compact instrument version): housing PBT, cover PBT, adapter PBT process connections: PPS
Control elements - one DIL switch for min/max position - one DIL switch for 0 s or 2 s switching delay - two DIL switches for setting the measuring ranges 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
Ambient temperature -40 ... 70 °C (-40 ... 158 °F) -40 ... 60 °C (233 ... 333 K) for output N1 (FEW58)
Storage temperature -40 ... 80 °C (-40 ... 176 °F)
Degree of protection IP66
Mass separate instrument version: - rod, 1 m (3 ft) long, LKL-P1 with 2, 3 or 5 rods: 415 g, 530 g, 760 g - rope, 1 m (3 ft) long, LKL-P2 with 2, 3 or 5 ropes: 390 g, 470 g, 640 g compact instrument version: - rod, 1 m (3 ft) long, LKL-P1 with 2 or 3 rods (600 g/720 g) - rope, 1 m (3 ft) long, LKL-P2 with 2 or 3 ropes (710 g/800 g)
Power consumption Output E5 (FEW52): P < 1.1 W output WA (FEW54): P < 2.0 W
Electromagnetic compatibility NE 21
Construction type LKL-P1: rod version LKL-P2: rope version
Measurement range A total of four measuring ranges (100 Ω, 1 kΩ, 10 kΩ, 100 kΩ) can be set via two DIL switches (SENS). The setting on delivery is 100 kΩ.
Marking II 2G Ex ia/ib IIC T4
Output signal see section electrical connection
Reference operating conditions ambient temperature: 23 °C (296 K), medium temperature: 23 °C (296 K), medium viscosity: medium must release the probe again (drain off), medium pressure pe: 0 bar, probe installation: vertically from above
Maximum measured error ± 10 % at 0.1 ... 100 kΩ ± 5 % at 1 ... 10 kΩ
Vibration resistance 20 ... 2000 Hz, 1 (m/s ) /Hz
Dimensions LKL-P1: - housing: max. Ø85 mm (3.3 inch), height max. 145 mm (5.7 inch) - rod: length 100 ... 4000 mm (4 in ... 13 ft) LKL-P2: - housing: max. Ø85 mm (3.3 inch), height max. 145 mm (5.7 inch) - rope: length 250 ... 15000 mm (10 in ... 49 ft)
Process connection - cylindrical thread G1½A to DIN ISO 228/1 - conical thread 1½ NPT to ANSI B 1.20.1
Reverse polarity protection output E5 (FEW52)
Hysteresis -10 % for the max probe, in reference to the switch point, Δs function deactivated
EU-type examination certificate TÜV 03 ATEX 2295
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Contact loading output WA (FEW54): 253 V AC/4 A, 30 V DC/4 A, 150 V/ 0.2 A
Directive 2014/30/EU EN 61326-1:2006 , EN 61326-2-3:2006
Shock resistance practical test
Directive 2014/34/EU EN 60079-0:2009 , EN 60079-11:2007
Display elements separate instrument version: dependent on the connected switching unit compact instrument version: output E5 (FEW52), WA (FEW54): - one red light emitting diode: fault message, switching status - one green light emitting diode: operation output N1 (FEW58): - one yellow light emitting diode: fault message, switching status - one green light emitting diode: operation
Equipment architecture probe with integrated electronic insert (compact instrument version) probe without integrated electronic insert (separate instrument version) for one, two or multiple point detection respectively, see section measuring system
Directive 2014/35/EU EN 61010-1:2001
Galvanic isolation output WA (FEW54): All input channels, output channels and relay contacts are galvanically isolated from each other.
Current consumption Output E5 (FEW52): I < 25 mA (without load) output WA (FEW54): 60 mA
Load Output E5 (FEW52): The load is switched via a transistor (PNP), cycled overload and short-circuit protection, continuous ≤ 200 mA (short-circuit proof), residual voltage at transistor at I 2.9 V Output WA (FEW54): Loads are switched via 2 potential-free change-over contacts. I~ max. 4 A, U~ max. 253 V P~ max. 1000 VA, cos φ = 1, P~ max. 700 VA, cos φ > 0.7 I- max. 4 A to 30 V, I- max. 0.2 A to 150 V When connecting a functional extra-low voltage circuit with double insulation in accordance with IEC 1010: The sum of the relay output and power supply voltages is max. 300 V. output N1 (FEW58): refer to datasheet of the connected switch amplifier acc. to IEC 60947-5-6 (NAMUR)
Switching delay A switching delay of 2.0 s can be activated or deactivated via a DIL switch. If the switching delay is set to 0 s, the device switches after approx. 0.3 s.
Influence of ambient temperature < 0.05 %/K
Mounting location The rod and rope probes are mounted predominantly in tanks made of plastic or metal.
Measured variable resistance change between two conductors caused by the presence or absence of a conductive product.
Climate class tropicalized
Non-repeatability ± 5 % at 0.1 ... 100 kΩ ± 1 % at 1 ... 10 kΩ
Switching time < 3 s
Medium temperature -40 ... 100 °C (-40 ... 212 °F)
Overspill protection see approval (ZE)
Supplementary documentation technical information TI375O operating instructions KA203O (LKL-P* without electronic insert) operating instructions KA204O (LKL-P* with integrated electronic insert) safety information SI230O (TÜV 03 ATEX 2295) safety information SI226O ( II 3G EEx nA [L] IIC T6 or nC [L]) approval ZE043O overspill protection acc. to WHG (Z-65.13-378) approval ZE257O leak detection system (Z-65.40-379)
Supply voltage Output E5 (FEW52): supply voltage 10.8 ... 45 V DC load connection: open collector; PNP switching voltage: max. 45 V Output WA (FEW54): supply voltage 20 ... 55 V DC or 20 ... 253 V AC, 50/60 Hz peak inrush current: max. 2 A, max. 400 µs output: two potential-free change-over contacts output N1 (FEW58): refer to datasheet of the connected switch amplifier acc. to IEC 60947-5-6 (NAMUR)
Measuring principle An alternating voltage exists between the probes in an empty tank. As soon as the conductive liquid in the tank creates a connection between the ground probe and, for example, the maximum probe, a measurable current flows and the device switches. With level limit detection, the device switches back as soon as the liquid clears the maximum probe. With two-point control, the device does not switch back until the max and min probe is cleared. Using alternating voltage prevents corrosion of the probes and electrolytic destruction of the product. The material used for the tank walls is not important for measurement because the system is designed as a closed potential-free circuit between the probes and the electronics. There is absolutely no danger if the probes are touched during operation.
Electrical connection cable connection M20x1.5, 1/2NPT, G1/2
Input signal probes covered - A measurable current is flowing between the probes. probes uncovered - There is no measurable current flowing between the probes.
Signal on alarm output N1 (FEW58): output signal with damaged sensor < 1 mA
Fail-safe mode Selecting the correct fail-safe mode ensures that the relay/the output always runs in quiescent current fail-safe. output E5 (FEW52): - maximum fail-safe: The output signal is < 1 mA if the switch point is exceeded (probe covered), a fault occurs or the power supply fails. - minimum fail-safe: The output signal is < 1 mA if the switch point is undershot (probe uncovered), a fault occurs or the power supply fails. Output WA (FEW54): - maximum fail-safe: The relay de-energises when the switch point is exceeded (probe covered), a fault occurs or the power supply fails. - minimum fail-safe: The relay de-energizes when the switch point is undershot (probe uncovered), a fault occurs or the power supply fails. output N1 (FEW58): - maximum fail-safe: The output voltage is 0 V if the switch point is exceeded (probe covered), a fault occurs or the power supply fails. - minimum fail-safe: The output voltage is 0 V if the switch point is undershot (probe uncovered), a fault occurs or the power supply fails.
Lead monitoring For probes without an electronic insert, an additional printed circuit board must be installed in the housing, which enables cable monitoring. It is always switched or connected between rod/rope 1 and 2. Note! When using switching units (transmitters) that do not support cable monitoring, these must be removed.
Mounting examples see section example applications
Medium pressure -1 ... 10 bar (-14.5 ... 145 psi)
Conductivity ≥ 10 µS
Probe rod probes: compact instrument version 2 or 3 rods, separate instrument version 2, 3 or 5 rods - diameter without insulation: Ø4 mm (0.16 inch) - rod length: 100 ... 4000 mm (4 in ... 13 ft) - thickness of insulation: 0.5 mm (0.02 inch) - length of non-insulated area (tip of rod): 20 mm (0.8 inch) - extraction forces: 1000 N rope probes: compact instrument version 2 or 3 ropes, separate instrument version 2, 3 or 5 ropes - diameter without insulation: Ø1 mm (0.04 inch) - rope length: 250 ... 15000 mm (10 inch ... 49 ft) - thickness of insulation: 0.75 mm (0.03 inch) - weight length: 100 mm (4 inch) (not insulated) - weight diameter: Ø10 mm (0.4 inch) - extraction forces: 500 N

Техподдержка

Опишитите свой вопрос, специалист службы технической поддержки свяжется с Вами в течении нескольких часов

Отправляя заявку, вы принимаете условия Политики конфиденциальности.

Спасибо!

Ваше сообщение успешно отправлено