  • Device for hydrostatic pressure measurement in liquids or paste-like media
  • Rod version
  • Modular probe program to ensure optimum process adaptation
  • Temperature range up to 85 °C (185 °F)
  • Pressure range up to 10 bar (150 psi)
  • Easy commissioning without the need for an operating tool
  • Configurable by PACTware
  • Up to SIL 2 acc. to IEC 61508
Параметр Значение
Общие характеристики
Артикул 59257
Материал process connections: AISI 316L (1.4435 or 1.4404), Alloy C276 (2.4819) housing: - die-cast aluminum with protective powder-coating on polyester base, housing F31 - stainless steel AISI 316L (1.4404), housing F15 rod: AISI 316L (1.4404) or Alloy C276 (2.4819) process isolating diaphragm: Alloy C276 (2.4819), Rhodium Gold Alloy C276, Platinum Gold Alloy C276 sealing measuring cell: welded measuring cell or FKM Viton, EPDM, Kalrez
Ambient temperature -40 ... 85 °C (-40 ... 185 °F) with display : -20 ... 70 °C (-4 ... 158 °F)
Storage temperature -40 ... 90 °C (-40 ... 194 °F)
Degree of protection IP66, NEMA 4X IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP69K (with separate housing and FEP cable)
Connection gland M20 thread M20, G1/2, NPT1/2 device plug M12 HAN7D Harting connector, angled valve connector acc. ISO 4400, cable 5 m
Rated voltage versions for safe area: 11.5 ... 35 V DC, HART, 2-wire 9 ... 32 V DC, PROFIBUS PA version for hazardous area see safety information (SI)
Measurement range 0.1 ... 10 bar max. turn down: 100:1
Output signal 4 ... 20 mA with superimposed digital communication protocol HART 6.0, 2-wire digital communication signal PROFIBUS PA (Profile 3.02)
Process connection threads ISO 228: G1/2, threads ANSI: NPT1/2 flanges EN 1092-1: DN 40 ... DN 100, flanges ANSI 16.5: 2 ... 4 in, flanges JIS B2220
CSA approval see instruction manuals (SI)
EU-type examination certificate see instruction manuals (SI)
IECEx approval see instruction manuals (SI)
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Designation see technical information (TI)
FM approval see instruction manuals (SI)
Directive 2014/30/EU EN 61326-1:2006 , EN 61326-2-3:2006 , EN 61326-2-5:2006
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-31:2009
Communication 4 ... 20 mA HART (standard) PROFIBUS PA (option)
Accuracy reference accuracy: 0.2 % (standard), 0.1 % (platinum) The reference accuracy comprises the non-linearity according to limit point setting, hysteresis and non-reproducibility acc. to IEC 60770. The data refer to the calibrated span.
Directive 2014/35/EU EN 61010-1:2010
Measured variable hydrostatic pressure
Medium temperature -40 ... 85 °C (-40 ... 185 °F)
Overspill protection see approval (ZE)
Supplementary documentation technical information (TI) manuals, brief instructions (BA, KA) instruction manuals (SI) control drawings (ZD) approval (ZE)
Long-term drift up to 0.05 % of upper range limit (URL)/year up to 0.125 % of upper range limit (URL)/5 years