  • Output: 28 ... 30 V/500 mA
  • High-power trunk for high device count and long cable lengths
  • With galvanic isolation
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • High efficiency, low heat dissipation for high packing density
  • Hot swappable in redundant configuration
  • Module exchange without tools during operation
Параметр Значение
Общие характеристики
Артикул 64398
Ambient temperature -40 ... 70 °C (-40 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Degree of protection IP20
Mass approx. 150 g
Rated voltage 28 ... 30 V
Electromagnetic compatibility NE 21:2011
Relative humidity < 95 % non-condensing
Mounting motherboard mounting
Housing width 18 mm
Housing depth 128 mm
Housing height 106 mm
Pollution degree max. 2, according to IEC 60664
Marking II 3 G Ex nA IIC T4 Gc
Vibration resistance 1 g , 10 ... 150 Hz
Connection type motherboard specific
Housing material Polycarbonate
Core cross-section motherboard specific
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Rated current 500 ... 10 mA
Directive 2014/30/EU EN 61326-1:2013
Shock resistance 15 g 11 ms
Certificate TÜV 04 ATEX 2500 X
Directive 2014/34/EU EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
Power dissipation typ. 1.8 W
Design / Mounting Motherboard based
Corrosion resistance acc. to ISA-S71.04-1985, severity level G3
FM certificate FM 19 US 0015 X and FM 19 CA 0011 X
FM marking AEx/Ex ec IIC T4
IECEx certificate IECEx TUN 13.0038X
IECEx marking Ex nA IIC T4 Gc
Marine approval pending
Fieldbus segment/Supply functional insulation acc. to IEC 62103, rated insulation voltage 250 V AC
Fieldbus standard IEC 61158-2
Short-circuit current 550 mA
LED ERR red flashing: short-circuit or undervoltage at output
LED PWR green if U > 28 V
Voltage 32 V