Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

Switch Amplifier KCD2-SON-Ex2.R1

Switch Amplifier KCD2-SON-Ex2.R1
Switch Amplifier KCD2-SON-Ex2.R1

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 58048
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • 2 passive transistor outputs (resistive)
  • Application-specific outputs
  • Line fault transparency (LFT)
  • Housing width 12.5 mm
  • Up to SIL 2 acc. to IEC 61508
Параметр Значение
Общие характеристики
Артикул 58048
Control elements DIP-switch
Ripple ≤ 10 %
Switching frequency ≤ 5 kHz
Response time ≤ 200 µs
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Degree of protection IP20
Connection screw terminals
Mass approx. 100 g
Rated voltage 19 ... 30 V DC with external resistance > 2 kΩ, e. g. 16-channel ProSafe DI card SDV144 from Yokogawa
Electromagnetic compatibility NE 21:2011 , EN 61326-3-2:2008
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Current 17.1 mA
Marking II 3G Ex ec IIC T4 Gc
Dimensions 12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
Labeling space for labeling at the front
EU-type examination certificate BASEEFA 13 ATEX 0080
IECEx approval IECEx BAS 13.0046 IECEx CML 19.0147X
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Approved for [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I Ex ec IIC T4 Gc
Power 45 mW (linear characteristic)
Rated current 35 ... 25 mA
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Certificate CML 19 ATEX 4410 X
Directive 2014/34/EU EN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012
Safety Integrity Level (SIL) SIL 2
Display elements LEDs
Optional accessories - power feed module KFD2-EB2(.R4A.B)(.SP) - universal power rail UPR-03(-M)(-S) - profile rail K-DUCT-BU(-UPR-03)
Power dissipation ≤ 750 mW
Configuration via DIP switches
Control drawing 116-0374 (cULus)
Voltage 10.5 V
Maximum safe voltage 253 V AC (Attention! The rated voltage can be lower.)
Connection side control side
Input Ex ia
Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Output/Output basic insulation according to EN 50178, rated insulation voltage 50 V
Line fault detection breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA
Signal type Digital Input
Rated values acc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit current approx. 10 V DC / approx. 8 mA
Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA
Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Output/power supply basic insulation according to EN 50178, rated insulation voltage 50 V
Protection against electrical shock IEC 61010-1:2010
Output I, II signal or error message, passive transistor output (resistive) 0-signal: 33 kΩ ± 5 % + voltage drop 6.5 V ± 0.5 V 1-signal: voltage drop 6.5 V ± 0.5 V fault: > 100 kΩ
Collective error message Power Rail
Pulse/Pause ratio min. 100 µs / min. 100 µs

Техподдержка

Опишитите свой вопрос, специалист службы технической поддержки свяжется с Вами в течении нескольких часов

Отправляя заявку, вы принимаете условия Политики конфиденциальности.

Спасибо!

Ваше сообщение успешно отправлено