Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Доставка в любой регион России транспортной
компанией на Ваш выбор
Параметр | Значение |
Общие характеристики | |
Артикул | 58512 |
Operating voltage | 20 ... 30 V DC , ripple 10 % ; 12 ... 20 V DC sensitivity reduced to 90 % |
No-load supply current | ≤ 20 mA |
Repeat accuracy | ± 1 mm |
Switching frequency | 10 Hz |
UL approval | cULus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient temperature | -10 ... 50 °C (14 ... 122 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Degree of protection | IP67 |
Housing | Polycarbonate |
Mass | 10 g |
Time delay before availability | ≤ 150 ms |
Voltage drop | ≤ 2 V |
Pulse length | ≥ 3 s |
Temperature influence | + 0.17 %/K |
Output type | 1 switch output PNP, NO |
Vibration resistance | 10 ... 55 Hz , Amplitude ± 1 mm |
Connection type | M8 x 1 connector , 4-pin |
Off-state current | ≤ 0.01 mA |
Standards | EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 |
LED yellow | switching state and flashing: Teach-In |
Adjustment range | 30 ... 100 mm |
Sensing range | 10 ... 100 mm |
Tightening torque, fastening screws | max. 0.2 Nm |
Dead band | 0 ... 10 mm |
Standard target plate | 20 mm x 20 mm |
Transducer frequency | approx. 400 kHz |
Input type | 1 program input |
Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
Rated operating current | 200 mA , short-circuit/overload protected |
Range hysteresis | typ. 2.5 mm |
Switch-on delay | ≤ 50 ms |
Shock resistance | 30 g , 11 ms period |
Rated operating voltage | 24 V DC |
Permissible cable length | max. 300 m |
Level | low level : 0 ... 0.7 V (Teach-In active) high level : U or open input (Teach-In inactive) |
Input impedance | 16 kΩ |
Installation position | any position |