Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Доставка в любой регион России транспортной
компанией на Ваш выбор
Параметр | Значение |
Общие характеристики | |
Артикул | 15010 |
Operating voltage | 10 ... 30 V DC , ripple 10 % |
No-load supply current | ≤ 50 mA |
Repeat accuracy | ≤ 1 % |
Switching frequency | max. 8 Hz |
UL approval | cULus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Degree of protection | IP67 |
Housing | brass, nickel-plated |
Mass | 60 g |
Voltage drop | ≤ 3 V |
Temperature influence | ± 1.5 % of full-scale value |
Output type | 1 switch output PNP Normally open/closed , programmable |
CSA approval | cCSAus Listed, General Purpose |
Connection type | Connector plug M12 x 1 , 5-pin |
Standards | EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 |
LED yellow | indication of the switching state flashing: program function object detected |
EAC conformity | TR CU 020/2011 |
Adjustment range | 50 ... 500 mm |
Sensing range | 30 ... 500 mm |
Dead band | 0 ... 30 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx. 380 kHz |
Response delay | approx. 50 ms |
LED red | solid red: Error red, flashing: program function, object not detected |
Input type | 1 program input, operating range 1: -U ... +1 V, operating range 2: +4 V ... +U input impedance: > 4.7 kΩ; program pulse: ≥ 1 s |
Transducer | epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT |
Rated operating current | 200 mA , short-circuit/overload protected |
Range hysteresis | 1 % of the set operating distance |
Beam width | wide |
Synchronization | 1 synchronous connection, bi-directional 0-level: -U ...+1 V 1-level: +4 V...+U input impedance: > 12 kΩ synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms |
Common mode operation | max. 95 Hz |
Multiplex operation | ≤ 95 Hz / n, n = number of sensors, n ≤ 5 |
Output | Switch point A1: 50 mm Switch point A2: 500 mm output function: Window mode output behavior: NO contact |