Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Доставка в любой регион России транспортной
компанией на Ваш выбор
Параметр | Значение |
Общие характеристики | |
Артикул | 40960 |
Operating voltage | 10 ... 30 V DC |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Degree of protection | IP54 |
Housing | ABS , PC (Polycarbonate) |
Mass | 500 g |
Power consumption | 2 VA |
Relative humidity | 90 % , noncondensing |
Operation indicator | LED green: power on |
Interface type | SSI interface |
Resolution | ± 0.6 mm (833.3 positions/m) |
Data flow indicator | LED yellow: data communication active |
Vibration resistance | DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles |
CSA approval | cCSAus Certified, General Purpose Class 2 power source |
Connection type | 8-pin, M12 x 1 connector |
Ordering information | Mounting plate included with delivery |
Emitted interference | DIN EN 61000-6-4 |
Noise immunity | DIN EN 61000-6-2 |
Shock resistance | DIN EN 60068-2-27, half sine 30 g, 18 ms |
Operating temperature | 0 ... 60 °C (32 ... 140 °F) |
Error indicator | LED red flashing: read head outside of code rail solid on: internal diagnostic test failed |
Data output code | binary code , 25 bit |
Measuring range | max. 152 m |
Passage speed | ≤ 4 m/s |
Clock frequency | 100 ... 1000 kHz |
Free tolerances to code rail | horizontal: 31 mm ( ± 15.5 mm ) vertical: 28 mm ( ± 14 mm ) |