Параметр | Значение |
Общие характеристики | |
Артикул | 40662 |
MTTF | 60 a |
Mission Time (T | 10 a |
Diagnostic Coverage (DC) | 0 % |
Operating voltage | 10 ... 30 V DC |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Degree of protection | IP54 |
Housing | ABS , PC (Polycarbonate) |
Mass | 500 g |
Power consumption | 11 VA at 24 V DC |
Relative humidity | 90 % , noncondensing |
Operation indicator | LED green: power on |
Interface type | RS 485 interface |
Resolution | ± 0.4 mm (1,250 positions/m) |
Transfer rate | 38.4 kBit/s |
Protocol | 3 , without parity (8 bits/byte) |
Data flow indicator | LED yellow: data communication active |
Vibration resistance | DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles |
CSA approval | cCSAus Certified, General Purpose Class 2 power source |
Connection type | 5-pin, M12 x 1 connector |
Ordering information | Mounting plate included with delivery |
Emitted interference | DIN EN 61000-6-4 , DIN EN 12015 |
Noise immunity | DIN EN 61000-6-2 , DIN EN 12016 |
Shock resistance | DIN EN 60068-2-27, half sine 30 g, 18 ms |
Operating temperature | -40 ... 60 °C (-40 ... 140 °F) |
Error indicator | LED red flashing: read head outside of code rail solid on: internal diagnostic test failed |
Termination | with RS 485 termination |
Data output code | binary code |
Measuring range | max. 314.5 m |
Passage speed | ≤ 12.5 m/s |
Free tolerances to code rail | horizontal: 31 mm ( ± 15.5 mm ) vertical: 28 mm ( ± 14 mm ) |
Address | 0 |