AS-Interface gateway VBG-PN-K20-DMD-EV2

AS-Interface gateway VBG-PN-K20-DMD-EV2
AS-Interface gateway VBG-PN-K20-DMD-EV2

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 72955
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • Connection to PROFINET IO
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • 2 AS-Interface networks
  • Integrated web server with extended functionality
  • Integrated switch allows line topology
Параметр Значение
Общие характеристики
Артикул 72955
UL approval An isolated source with a secondary open circuit voltage of ≤ 30 V with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device.
Ambient temperature 0 ... 55 °C (32 ... 131 °F)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Degree of protection IP20
Housing Stainless steel
Mass 500 g
Electromagnetic compatibility EN 61000-6-2:2005, EN 61000-6-4:2007
Construction type Low profile housing , Stainless steel
Interface type Chip card slot
Transfer rate 10 MBit/s / 100 MBit/s , Automatic baud rate detection
Protocol Media Redundancy Protocol (MRP)
Rated operating current ≤ 250 mA PELV
Directive 2014/30/EU EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007
Physical 2 x RJ-45
Rated operating voltage from AS-Interface
UL File Number E223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source
Button 4
AS-Interface specification V3.0
Duplicate address detection from AS-Interface slaves
Earth fault detection integrated
EMC monitoring integrated
Diagnostics function Extended function via display
Display Illuminated graphical LC display for addressing and error messages
LED ETHERNET ethernet active; LED green
LED AS-i ACTIVE AS-Interface operation normal; LED green
LED CONFIG ERR configuration error; LED red
LED PRG ENABLE autom. programming; LED green
LED POWER voltage ON; LED green
LED PRJ MODE projecting mode active; LED yellow
LED U AS-i AS-Interface voltage; LED green
Insulation voltage ≥ 500 V
AS-Interface EN 62026-2:2013
Switch SET Selection and setting of a slave address
OK button Mode selection traditional-graphical/confirmation
Button MODE Mode selection PRJ-operation/save configuration/cursor
ESC button Mode selection traditional-graphical/cancel
PROFINET RJ-45