AS-Interface gateway VBG-ENX-K20-D

AS-Interface gateway VBG-ENX-K20-D
AS-Interface gateway VBG-ENX-K20-D

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 44758
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • Gateway compliant with AS-Interface specification 3.0
  • Connection to Ethernet Modbus TCP/IP
  • Dublicate addressing detection
  • Integrated webserver
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • Integrated switch allows line topology
  • DLR technology supports ring topology
Параметр Значение
Общие характеристики
Артикул 44758
MTTF 105 a at 30 °C
UL approval An isolated source with a secondary open circuit voltage of ≤ 30 V with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device.
Ambient temperature 0 ... 55 °C (32 ... 131 °F)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Degree of protection IP20
Mass 500 g
Electromagnetic compatibility EN 61000-6-2:2005, EN 61000-6-4:2007
Construction type Low profile housing , Stainless steel
Interface type Chip card slot
Transfer rate 19,2 kBit/s
Protocol EtherNet/IP + MODBUS TCP/IP acc. to IEEE 802.3 supports device level ring protocol DLR
Standards EN 61000-6-2:2005, EN 61000-6-4:2007 EN 954-1:1996 (up to Kategorie 4), IEC 61508:2001 and EN 62061:2005 (up to SIL3) EN 13849:2008 (PL e)
EAC conformity TR CU 020/2011
Rated operating current ≤ 300 mA from AS-Interface
Directive 2014/30/EU EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007
Rated operating voltage from AS-Interface 30 V DC
UL File Number E223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source
Button 4
AS-Interface specification V3.0
PLC-Functionality activateable
Duplicate address detection from AS-Interface slaves
Earth fault detection integrated
EMC monitoring integrated
Diagnostics function Extended function via display
Display Illuminated graphical LC display for addressing and error messages
LED ETHERNET ethernet active; LED green
LED AS-i ACTIVE AS-Interface operation normal; LED green
LED CONFIG ERR configuration error; LED red
LED PRG ENABLE autom. programming; LED green
LED POWER voltage ON; LED green
LED PRJ MODE projecting mode active; LED yellow
LED U AS-i AS-Interface voltage; LED green
Insulation voltage ≥ 500 V
Ethernet RJ-45
AS-Interface EN 62026-2:2013