Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Доставка в любой регион России транспортной
компанией на Ваш выбор
Параметр | Значение |
Общие характеристики | |
Артикул | 41188 |
Ambient temperature | -20 ... 55 °C (-4 ... 131 °F) |
Degree of protection | IP67 |
Connection | M12 x 1 connector |
Housing | Fiberglass-reinforced thermoplastic |
Mass | approx. 0.5 kg |
Current | 300 mA |
B | 5 E+6 |
Life span | 10 switching cycles |
Rated insulation voltage | 50 V |
Rated operating current | ≤ 45 mA |
Directive 2014/30/EU | EN 62026-2:2013 |
Supply | from AS-Interface |
Operating force | 35 N |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
Number/Type | 1 guard locking magnet, 1 LED red, 1 LED green |
Performance level (PL) | PL d |
Functional safety | DIN EN 954-1, EN ISO 13849-1 (up to PL ) |
AS-Interface specification | V2.1 |
LED POWER | AS-Interface voltage; LED green |
AS-Interface | EN 62026-2:2013 |
Slave type | Safety-Slave |
Required master specification | ≥ V2.0 |
Profile | S-7.B |
IO code | 7 |
ID code | B |
ID1 code | F |
ID2 code | E |
D0 | door-monitoring contact SK guard locking magnet |
D1 | door-monitoring contact SK LED red |
D2 | Magnet-monitoring contact MC LED green |
D3 | Magnet-monitoring contact MC - |
LED FAULT | error display; LED red red: communication error |
Auxiliary voltage | Guard locking magnet: 24 V DC +10/-15 % PELV |
guard-locking mode | working current |
approach speed | max. 20 m/min |
Extraction force | 30 N (not interlocked) |
retention force | 20 N |
locking force | max. 2500 N 2000 N , F as per inspection policy GS-ET-19 |
approach direction lateral | 24.5 mm 5 mm |
approach direction from above | 24.5 mm 5 mm |
actuating head | metal |
cam | stainless steel |