Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

AS-Interface sensor/actuator module VBA-2E1A-G10-ZAL/E2L-1M-V1-Y

AS-Interface sensor/actuator module VBA-2E1A-G10-ZAL/E2L-1M-V1-Y
AS-Interface sensor/actuator module VBA-2E1A-G10-ZAL/E2L-1M-V1-Y

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 64983
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • Ultra-compact enclosure
  • Gold-plated and machined contacts
  • One piece housing
  • Degree of protection IP68 / IP69K
  • Direct connection via cable outlet
Параметр Значение
Общие характеристики
Артикул 64983
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Degree of protection housing: IP67 IP67 / IP68 / IP69K with flat cable VAZ-FK-S-* M12 socket: IP69K
Connection AS-Interface/U : AS-Interface flat cable Inputs/outputs: M12 round connector, 4-pin, A-coded, according to IEC 61076-2-101:2012 WAGO terminal type 733-105
Housing PBT PC
Mass 100 g
Switching point according to DIN EN 61131-2 (Type 2)
Protection class III
Contacts M12: CuSn/Au WAGO terminal: CrNi
Body black PUR
Cable PUR
Sheath diameter ∅4,3 mm
Color black
Cores 0.34 mm
Length 1 m
Vibration resistance 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Shock and impact resistance 30 , 11 ms in 6 spatial directions 3 shocks 10 , 16 ms in 6 spatial directions 1000 shocks
Tightening torque, fastening screws 1.65 Nm
Rated operating current ≤ 40 mA / max. 60 mA
Emitted interference EN 61000-6-4:2007/A1:2011
Noise immunity EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
Directive 2014/30/EU EN 62026-2:2013
Supply from external auxiliary voltage U
Fieldbus standard EN 62026-2:2013
Voltage ≥ (U - 0.5 V)
Mounting screw Stainless steel 1.4305 / AISI 303
Current loading capacity ≤ 1000 mA overload and short-circuit resistant
Rated operating voltage 18.5 ... 31.6 V from AS-Interface
Number/Type 1 electronic output, PNP,
Surge protection U , U : Over voltage category III, safe isolated power supplies (PELV)
Signal delay < 1 ms (input/AS-Interface)
Input current ≤ 9 mA (limited internally)
AS-Interface specification V3.0
AS-Interface EN 62026-2:2013
Slave type A/B slave
Required master specification ≥ V2.1
LED IN switching state (input); 2 LED yellow
0 (unattenuated) ≤ 3 mA
1 (attenuated) ≥ 5 mA
Input EN 61131-2:2007
Profile S-7.A.E
IO code 7
ID code A
ID1 code 7
ID2 code E
D0 IN1 O1
D1 IN2 -
D2 - -
D3 - -
P0 communication monitoring P0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition
P1 Input filter P1 = 0 input filter on, pulse suppression ≤ 2 ms P1 = 1 input filter off (default settings)
P2 Synchronous mode P2 = 0 synchronous mode on P2 = 1 synchronous mode off (default settings)
P3 not used
Tightening torque, cable gland 0.4 Nm
LED FAULT error display; LED red red: communication error or address is 0 red flashing: overload of sensor power supply or overload of outputs or external auxiliary voltage U missing
LED AS-i AS-Interface voltage; LED green
LED OUT Switching state (output); LED yellow
Auxiliary voltage 20 ... 30 V DC PELV

Техподдержка

Опишитите свой вопрос, специалист службы технической поддержки свяжется с Вами в течении нескольких часов

Отправляя заявку, вы принимаете условия Политики конфиденциальности.

Спасибо!

Ваше сообщение успешно отправлено