Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

AS-Interface sensor/actuator module VBA-4E4A-G12-XEL

AS-Interface sensor/actuator module VBA-4E4A-G12-XEL
AS-Interface sensor/actuator module VBA-4E4A-G12-XEL

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 47640
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • One-piece housing with stainless steel base
  • Installation without tools
  • Metal threaded inserts with SPEEDCON technology
  • Flat cable connection with cable piercing technique, variable flat cable guide
  • Communication monitoring, configurable
  • Inputs for 2- and 3-wire sensors
  • DIN rail mounting
  • Sensor supply powered by AUX
  • Input and output connection on each M12 connector
Параметр Значение
Общие характеристики
Артикул 47640
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Degree of protection IP67
Connection Cable piercing method flat cable yellow/flat cable black inputs/outputs: M12 round connector
Housing PBT
Mass 200 g
Switching point according to DIN EN 61131-2 (Type 2)
Relative humidity 85 % , noncondensing
Altitude ≤ 2000 m above MSL
Mounting Mounting plate
Protection class III
Current 1 A per output
Pollution degree 3
Vibration resistance 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Shock and impact resistance 30 , 11 ms in 6 spatial directions 3 shocks 10 , 16 ms in 6 spatial directions 1000 shocks
Rated operating current ≤ 40 mA
Emitted interference EN 61000-6-4:2007
Noise immunity EN 61000-6-2:2005 EN 62026-2:2013
Directive 2014/30/EU EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007
Supply from external auxiliary voltage U
Fieldbus standard EN 62026-2:2013
LED PWR AS-Interface voltage; green LED green: voltage OK flashing green: address 0
Voltage ≥ (U - 0.5 V)
Climatic conditions For indoor use only
Current loading capacity ≤ 500 mA overload and short-circuit resistant
Rated operating voltage 26.5 ... 31.6 V from AS-Interface
UL File Number E223772
Number/Type 4 electronic outputs, PNP, overload and short-circuit proof
Surge protection U , U : Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral
Signal delay < 1 ms (input/AS-Interface)
Input current ≤ 8 mA (limited internally)
AS-Interface specification V3.0
LED AUX ext. auxiliary voltage U ; dual LED green/red green: voltage OK red: reverse voltage
AS-Interface EN 62026-2:2013
Slave type A/B slave
Required master specification ≥ V3.0
LED IN switching state (input); 4 LED yellow
0 (unattenuated) ≤ 2 mA
1 (attenuated) ≥ 6 mA
Input EN 61131-2:2007
Profile S-7.A.7
IO code 7
ID code A
ID1 code 7
ID2 code 7
D0 IN1 OUT1
D1 IN2 OUT2
D2 IN3 OUT3
D3 IN4 OUT4
P0 communication monitoring P0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition
P1 Input filter P1 = 0 input filter on, pulse suppression ≤ 2 ms P1 = 1 input filter off (default settings)
P2 Synchronous mode P2 = 0 synchronous mode on P2 = 1 synchronous mode off (default settings)
P3 not used
Tightening torque, cable gland 0.4 Nm
LED FAULT error display; LED red red: communication error or address is 0 red flashing: overload of sensor power supply or outputs
Auxiliary voltage 24 V DC ± 15 % PELV

Техподдержка

Опишитите свой вопрос, специалист службы технической поддержки свяжется с Вами в течении нескольких часов

Отправляя заявку, вы принимаете условия Политики конфиденциальности.

Спасибо!