  • AS-Interface certificate
  • Degree of protection IP67
  • Addressing jack
  • Flat cable connection with cable piercing technique, variable flat cable guide
  • Communication monitoring
  • Inputs for 2-, 3-, and 4-wire sensors
  • Power supply of outputs from the external auxiliary voltage
  • Supply for inputs from AS-Interface
  • Ground connection (FE) possible
  • Function display for bus, ext. auxiliary voltage, inputs and outputs
  • Detection of overload on sensor supply
  • Detection of output overload
Параметр Значение
Общие характеристики
Артикул 26869
MTTF 140 a
Mission Time (T 20 a
Diagnostic Coverage (DC) 0 %
Ambient temperature -25 ... 60 °C (-13 ... 140 °F)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Degree of protection IP67
Connection Cable piercing method flat cable yellow/flat cable black inputs/outputs: M12 round connector
Housing PBT
Mass 150 g
Switching point according to DIN EN 61131-2 (Type 2)
Relative humidity 85 % , noncondensing
Altitude ≤ 2000 m above MSL
Mounting Mounting plate
Protection class III
Current 0.5 A per output , 2 A total
Pollution degree 3
Rated operating current ≤ 40 mA (without sensors) / max. 220 mA
Emitted interference EN 61000-6-4:2001
Noise immunity EN 61000-6-2:2001
Directive 2014/30/EU EN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001
Supply from external auxiliary voltage U
Fieldbus standard EN 62026-2:2013
LED PWR AS-Interface voltage; LED green
Voltage ≥ (U - 0.5 V)
Climatic conditions For indoor use only
Current loading capacity ≤ 180 mA (T ≤ 40 °C), ≤ 140 mA (T ≤ 60 °C), , overload and short-circuit protected
Rated operating voltage 26.5 ... 31.6 V from AS-Interface
UL File Number E223772
Number/Type 4 electronic outputs, PNP, overload and short-circuit proof
Surge protection U , U : Over voltage category III, safe isolated power supplies (PELV)
Signal delay < 2 ms (input/AS-Interface)
Input current ≤ 9 mA (limited internally)
Signal frequency ≤ 250 Hz
AS-Interface specification V3.0
LED AUX ext. auxiliary voltage U ; LED green
AS-Interface EN 62026-2:2013
Slave type A/B slave
Required master specification ≥ V3.0
LED IN switching state (input); 4 LED yellow
0 (unattenuated) ≤ 3 mA
1 (attenuated) ≥ 5 mA
Input EN 61131-2:2007
Profile S-7.A.7
IO code 7
ID code A
ID1 code 7
ID2 code 7
D0 IN1 OUT1
D1 IN2 OUT2
D2 IN3 OUT3
D3 IN4 OUT4
P0 communication monitoring P0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition
P1 not used
P2 not used
P3 not used
Tightening torque, cable gland 0.4 Nm
LED FAULT error display; LED red red: communication error or address is 0 red flashing: overload of sensor power supply or outputs
Auxiliary voltage (output) 20 ... 30 V DC PELV
LED OUT Switching state (output); 4 LED yellow