Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

Retroreflective sensor MLV12-54/32/82b/124

Retroreflective sensor MLV12-54/32/82b/124
Retroreflective sensor MLV12-54/32/82b/124

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 4355
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • Robust photoelectric sensor series in a widely used standard housing
  • Resistant against noise: reliable operation under all conditions
  • Clear and functional display concept for the operating modes
  • High level of stability thanks to the metal housing frame
  • Tightly sealed thanks to welded plastic components
  • Suitable for operation at low temperatures down to -40 °C
Параметр Значение
Общие характеристики
Артикул 4355
Light source LED
Light type modulated visible red light , 660 nm
MTTF 1000 a
Mission Time (T 20 a
Diagnostic Coverage (DC) 0 %
Function indicator 2 LEDs yellow, light up when light beam is free, flash when falling short of the stability control, off when light beam is interrupted
Control elements rotary switch for light/dark, sensitivity adjuster
Operating voltage 10 ... 30 V DC
Ripple max. 10 %
No-load supply current max. 40 mA
Switching type light/dark on switchable
Signal output 1 PNP output, short-circuit protected, reverse polarity protected, open collector
Switching voltage max. 30 V DC
Switching current max. 0.2 A
Switching frequency 1000 Hz
Response time 0.5 ms
Product standard EN 60947-5-2
UL approval cULus
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient temperature -40 ... 60 °C (-40 ... 140 °F)
Storage temperature -40 ... 75 °C (-40 ... 167 °F)
Degree of protection IP67
Connection Metal connector, M12, 5-pin, 90° rotatable
Housing Frame: nickel plated, die cast zinc, Laterals: glass-fiber reinforced plastic PC
Optical face Plastic pane
Mass 60 g
Effective detection range 0 ... 6.5 m
Threshold detection range 9 m
Angle of divergence 1.5 °
Operation indicator LED green, flashes in case of short-circuit
Pre-fault indication output 1 PNP, inactive when level falls below function reserve after approx. 5 s. Immediately inactive if the beam is interrupted 4 times during the flashtime.
Voltage drop ≤ 2.5 V DC
Protection class II, rated voltage ≤ 300 V AC with pollution degree 1-2 according to IEC 60664-1
Housing width 41.5 mm
Housing depth 15 mm
Reference target H85-2 reflector
Diameter of the light spot approx. 170 mm at detection range 6.5 m
Housing height 49 mm
Vibration resistance IEC / EN 60068-2-6. Sinus. 10 -150 Hz, 5 g in each X, Y and Z directions
Continuous light 50000 Lux
Shock and impact resistance IEC / EN 60068. half-sine, 40 g in each X, Y and Z directions
Reflector distance 0.01 ... 6.5 m
Polarization filter yes
Modulated light 5000 Lux

Техподдержка

Опишитите свой вопрос, специалист службы технической поддержки свяжется с Вами в течении нескольких часов

Отправляя заявку, вы принимаете условия Политики конфиденциальности.

Спасибо!

Ваше сообщение успешно отправлено