Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

Safety light grid with integrated control unit SLPCM65-3-L

Safety light grid with integrated control unit SLPCM65-3-L
Safety light grid with integrated control unit SLPCM65-3-L

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 3624
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • Sensing range up to 65 m
  • 3-radial design
  • Beam spacing 400 mm
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Red transmission light
  • Usable with or without start/restart disable
  • Sequential and parallel muting in various operating modes
  • Emergency muting for the correction of the material jam
  • Integrated relay monitor
  • 7-segment diagnostic display
  • Integrated function display
  • Pre-fault indication
  • OSSD outputs as semiconductor or relay outputs
Параметр Значение
Общие характеристики
Артикул 3624
Light source LED
Light type modulated visible red light
Target size static: 32 mm dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Mission Time (T 20 a
Function indicator LED red: per receiver channel off: interruption flashes: receiver continuously on: reception with sufficient stability control on the front plate: LED red: OSSD off LED green: OSSD on LED yellow: types of muting operation
Operating voltage 24 V DC -15% / +25% , galvanically isolated
Signal output 1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltage Operating voltage -2 V
Switching current max. 0.5 A
Product standard EN 61496-1 ; IEC 61496-2
Degree of protection IP65
Connection M16 cable gland , terminal compartment with cage terminals, M12 connector for transmitters, muting lamp, etc., muting sensors, lamp socket for muting lamp, etc.
Effective detection range 12 ... 65 m
Beam spacing 400 mm
Number of beams 3
Operating mode Start/restart disable, relay monitor, muting operating modes
Angle of divergence < 5 °
Function input Relay monitor, start release, muting sensors (max. 4)
Marking CE
Emitter SLP65-3-T
Receiver SLPCM65-3-R-L
Category Cat. 4
Diagnostics indicator 7-segment display
Performance level (PL) PL e
Functional safety ISO 13849-1
PFH 3.54 E-9
Pre-fault indicator LED red next to receiver flashes
Safety output 2 separated fail safe semiconductor outputs
Safety type according to IEC/EN 61496 4