Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

Safety light grid with integrated control unit SLPCM8-2/31

Safety light grid with integrated control unit SLPCM8-2/31
Safety light grid with integrated control unit SLPCM8-2/31

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 3601
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • Sensing range up to 8 m
  • 2-radial design
  • Beam spacing 500 mm
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Minimum wiring expense due to transceiver with passive mirror column
  • Red transmission light
  • Usable with or without start/restart disable
  • Sequential and parallel muting in various operating modes
  • Emergency muting for the correction of the material jam
  • Integrated relay monitor
  • 7-segment diagnostic display
  • Pre-fault indication
  • OSSD outputs as semiconductor or relay outputs
Параметр Значение
Общие характеристики
Артикул 3601
Light source LED
Light type modulated visible red light
Target size static: 32 mm dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Mission Time (T 20 a
Function indicator LED red: per receiver channel off: interruption flashes: receiver continuously on: reception with sufficient stability control on the front plate: LED red: OSSD off LED green: OSSD on LED yellow: types of muting operation
Operating voltage 24 V DC -15% / +25% , galvanically isolated
Signal output 1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltage 20 ... 60 V DC, 12 ... 25 V AC
Switching current 0.01 ... 2 A
Product standard EN 61496-1 ; IEC 61496-2
Degree of protection IP65
Connection M16 cable gland , terminal compartment with cage-terminals, M12-connector for emitter, muting lamp as well as other muting sensors
Effective detection range 0.2 ... 8 m
Beam spacing 500 mm
Number of beams 2
Operating mode Start/restart disable, relay monitor, muting operating modes
Angle of divergence < 5 °
Function input Relay monitor, start release, muting sensors (max. 4)
Marking CE
B see instruction manuals
Category Cat. 4
Diagnostics indicator 7-segment display
Performance level (PL) PL e
Functional safety ISO 13849-1
PFH 3.54 E-9
Pre-fault indicator LED red next to receiver flashes
Safety output 2 relay outputs, force-guided NO-contact
Safety type according to IEC/EN 61496 4
Transceiver SLPCM8-2-A/31
Mirror pillar SLP8-2-M

Техподдержка

Опишитите свой вопрос, специалист службы технической поддержки свяжется с Вами в течении нескольких часов

Отправляя заявку, вы принимаете условия Политики конфиденциальности.

Спасибо!

Ваше сообщение успешно отправлено