Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Доставка в любой регион России транспортной
компанией на Ваш выбор
Параметр | Значение |
Общие характеристики | |
Артикул | 10349 |
MTTF | 11774 a |
Mission Time (T | 20 a |
Diagnostic Coverage (DC) | 0 % |
Switching frequency | 0 ... 3000 Hz |
UL approval | cULus Listed, General Purpose |
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
Degree of protection | IP68 |
Bending radius | > 10 x cable diameter |
Output type | 2-wire |
Switching function | Normally closed (NC) |
Rated operating distance | 5 mm |
Installation | non-flush |
Assured operating distance | 0 ... 4.05 mm |
Connection type | cable PVC , 2 m |
Housing material | PVDF |
Sensing face | PVDF |
Hysteresis | typ. % |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions |
Core cross-section | 0.34 mm |
CE marking | [*PD-Z02585A*] |
Nominal voltage | 8 V |
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. |
Appropriate type | NJ 5-11-N... |
Effective internal capacitance | max. 45 µF A cable length of 10 m is considered. |
Effective internal inductance | max. 50 µH A cable length of 10 m is considered. |
Use in the hazardous area | see instruction manuals |
Category | 2G |
Measuring plate not detected | min. 3 mA |
Measuring plate detected | ≤ 1 mA |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. |
Reduction factor r | 0.85 |