Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Доставка в любой регион России транспортной
компанией на Ваш выбор
Параметр | Значение |
Общие характеристики | |
Артикул | 25008 |
Operating voltage | 10 ... 30 V DC , ripple 10 % |
No-load supply current | ≤ 30 mA |
Repeat accuracy | ≤ 1 % |
Switching frequency | ≤ 13 Hz |
UL approval | cULus Listed, Class 2 Power Source |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Degree of protection | IP67 |
Housing | brass, nickel-plated |
Mass | 25 g |
Voltage drop | ≤ 3 V |
Temperature influence | ± 1.5 % of full-scale value |
Output type | 1 switch output NPN Normally open/closed , programmable |
Connection type | Connector M12 x 1 , 4-pin |
LED yellow | indication of the switching state flashing: program function object detected |
Adjustment range | 20 ... 200 mm |
Sensing range | 15 ... 200 mm |
Dead band | 0 ... 15 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx. 400 kHz |
Response delay | approx. 30 ms |
LED red | solid red: Error red, flashing: program function, object not detected |
Input type | 1 program input operating distance 1: -U ... +1 V, operating distance 2: +6 V ... +U input impedance: > 4,7 kΩ program pulse: ≥ 1 s |
Transducer | epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT |
Rated operating current | 100 mA , short-circuit/overload protected |
Default setting | Switch point A1: 20 mm Switch point A2: 200 mm |
Range hysteresis | 1 % of the set operating distance |