Параметр | Значение |
Общие характеристики | |
Артикул | 1481 |
Operating voltage | 10 ... 30 V DC , ripple 10 % |
No-load supply current | ≤ 50 mA |
Repeat accuracy | ≤ 0.5 % of switching point |
Switching frequency | ≤ 1.5 Hz |
UL approval | cULus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Degree of protection | IP65 |
Housing | nickel plated brass; plastic components: PBT |
Mass | 180 g |
Voltage drop | ≤ 2.5 V |
Temperature influence | < 2 % of far switch point |
Output type | 1 switch output NPN , Normally open/closed , programmable |
CSA approval | cCSAus Listed, General Purpose |
Connection type | Connector M12 x 1 , 5-pin |
LED green | solid: Power-on flashing: program function object detected |
LED yellow | solid: switching state switch output flashing: program function |
Adjustment range | 240 ... 4000 mm |
Sensing range | 200 ... 4000 mm |
Dead band | 0 ... 200 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx. 85 kHz |
Response delay | approx. 325 ms |
LED red | normal operation: "fault" program function: no object detected |
Input type | 1 program input, operating range 1: -U ... +1 V, operating range 2: +4 V ... +U input impedance: > 4.7 kΩ; program pulse: ≥ 1 s |
Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
Rated operating current | 200 mA , short-circuit/overload protected |
Range hysteresis | 1 % of the set operating distance |
Synchronization | bi-directional 0 level -U ...+1 V 1 level: +4 V...+U input impedance: > 12 KOhm synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms |
Common mode operation | max. 13 Hz |
Multiplex operation | ≤ 13 Hz / n , n = number of sensors , n ≤ 5 |