Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Доставка в любой регион России транспортной
компанией на Ваш выбор
Параметр | Значение |
Общие характеристики | |
Артикул | 89436 |
MTTF | 1640 a |
Mission Time (T | 20 a |
Diagnostic Coverage (DC) | 0 % |
Operating voltage | 10 ... 65 V |
Ripple | 10 % |
No-load supply current | ≤ 10 mA |
Repeat accuracy | 0.1 mm |
Switching frequency | 0 ... 1200 Hz |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Degree of protection | IP68 |
Mass | 20 g |
Voltage drop | ≤ 2.5 V |
Operating current | 0 ... 300 mA |
Output type | 3-wire |
Switching function | Normally open (NO) |
Rated operating distance | 2 mm |
Installation | flush |
Output polarity | DC |
Assured operating distance | 0 ... 1.62 mm |
A | 0 mm |
B | 0 mm |
C | 6 mm |
F | 12 mm |
Reverse polarity protection | yes |
Short-circuit protection | yes |
Switching state indicator | Multihole-LED, yellow |
Connection type | Connector M12 x 1 , 4-pin |
Housing material | brass, nickel-plated |
Sensing face | PPS |
Hysteresis | 0.02 ... 0.44 |
Off-state current | 0.01 mA |
E1 Type approval | 10R-04 |
Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 12 mm x 12 mm x 1 mm |
Reduction factor r | 0.4 |
Overload resistance | yes |
Wire breakage protection | yes |
Inductive overvoltage protection | yes |
Surge suppression | yes |