Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Доставка в любой регион России транспортной
компанией на Ваш выбор
Параметр | Значение |
Общие характеристики | |
Артикул | 7530 |
MTTF | 2240 a |
Mission Time (T | 20 a |
Diagnostic Coverage (DC) | 0 % |
Operating voltage | 5 ... 25 V |
UL approval | cULus Listed, General Purpose |
Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
Degree of protection | IP67 |
Time delay before availability | ≤ 5 ms |
Bending radius | > 10 x cable diameter |
Length | 4 mm |
Output type | 2-wire |
Switching function | Normally closed (NC) |
Reverse polarity protection | reverse polarity protected |
CSA approval | cCSAus Listed, General Purpose |
Connection type | cable PVC , 2 m |
Housing material | PBT |
Hysteresis | typ. 1 % |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions |
Core cross-section | 0.14 mm |
CE marking | [*PD-Z02585A*] |
Inside diameter | 15 mm |
Control drawing | 116-0165 |
Nominal voltage | 8.2 V (R approx. 1 kΩ) |
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
ATEX marking | II 2G Ex ia IIC T6…T1 Gb The Ex-related marking can also be printed on the enclosed label. |
Appropriate type | RC15-...-N3... |
Effective internal capacitance | max. 90 nF ; a cable length of 10 m is considered. |
Effective internal inductance | max. 70 µH ; a cable length of 10 m is considered. |
Use in the hazardous area | see instruction manuals |
Category | 2G |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. |
Diameter | 3 mm |
Passage speed | ≤ 10 m/s |
Measuring cylinder | Fe-metal |
Traverse A | 1 mA |
Traverse B | 3 mA |