Параметр | Значение |
Общие характеристики | |
Артикул | 50672 |
Mission Time (T | 20 a |
Diagnostic Coverage (DC) | 0 % |
Operating voltage | 10 ... 30 V |
Ripple | 10 % |
No-load supply current | ≤ 7 mA |
Repeat accuracy | 0.4 mm |
Switching frequency | 0 ... 300 Hz |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
Degree of protection | IP67 |
Mass | 107 g |
Voltage drop | ≤ 2.5 V |
Operating current | 0 ... 200 mA |
Output type | PNP |
Switching function | Normally closed (NC) |
Rated operating distance | 15 mm |
Installation | non-flush |
Output polarity | DC |
Assured operating distance | 0 ... 12.15 mm |
A | 15 mm |
B | 30 mm |
C | 25 mm |
F | 80 mm |
Reverse polarity protection | yes |
Short-circuit protection | yes |
Switching state indicator | Multihole-LED, yellow |
Connection type | Connector M12 x 1 , 3-pin |
Housing material | brass, nickel-plated |
Sensing face | PBT |
Housing diameter | 30 mm |
Hysteresis | 0.04 ... 3.3 mm |
Off-state current | ≤ 0.01 mA |
Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 45 mm x 45 mm x 1 mm |
Reduction factor r | 0.4 |
Overload resistance | yes |
Wire breakage protection | yes |
Inductive overvoltage protection | yes |